EMC. A beginners guide to EMC testing from Gainspeed

EMC – The black Art, but it doesn’t have to be!

EMC hurdleHere at Gainspeed we get a lot of new customers with little experience in EMC testing and occasionally they fall at the first hurdle, when it comes to testing their products.

So, we prepared a simple guide on what to expect and how to best prepare for testing new products for EMC:

 

Step 1: Initial inquiry

After speaking with us and answering a few basic questions about the EUT (Equipment Under Test) we will help you identify what standards and tests are applicable to your product.

 

Step 2: Pre-Compliance tests

If your product has not been previously assessed for EMC or has been significantly modified since its last assessment, we always recommend a one day (or half a day for simple products) pre-compliance testing. At this stage, we will identify obvious failures and could save you allot of time and money!

 

Step 3 – Compliance Assessment

Assuming all goes well with pre-compliance and if you wish to proceed to Compliance assessment. We can create a test plan for you that will detail which tests are required, including levels and limits. Once the test plan is agreed we can schedule a test date for you or your team to attend the lab and begin the tests. We may not need to repeat tests carried out during the pre-compliance stage if the data can be used for the final report.

 

Now the details:

 

Preparation – Part 1

EMC testing can be destructive and if you have concerns that some of the tests may affect your EUT please contact us beforehand and discuss them with us. Often EMC is an afterthought in the design process and this can make solving problems during testing very time consuming and even costly.

As mentioned above, we highly recommend you request some Pre-EMC investigation testing before booking the full tests. Basically, a quick check of radiated emissions, conducted emissions and ESD (Possibly some transients and surges). This can save a lot of time in the long run as making changes half way through the test plan will mean you may need to retest previous measurements. This is common mistake made by clients that can increase overall test times considerably.

Consider that any changes of significance made to the EUT to fix EMC problems may need to be retested for other tests to confirm it has no detrimental effects.
You also need to consider modes of operation, we can advise you on this, but to test correctly it needs to be operated in the worst case. To identify worst case requires pre-testing, and often still requires tests to be repeated in different operating modes where applicable.
To help you pre-assess your EUT, here is a list of related test areas that need to be considered.

 

ESD (Electro static discharges)

ESD is a simulation of static electricity from humans and other electrical sources. Its often applied at very high voltage (KV) for very short periods to any surface area of your EUT that can be accessed during normal operation. As a precaution, any static sensitive electronics should be isolated and sufficiently protected by either ESD protective components or by adequate housing.
A good guide is to pre-check your EUT for areas that can be susceptible. For example large gaps or vents that have sensitive components close inside.

ESD discharges of significant voltage will jump gaps through the air!

Also, consider metal areas like connectors, what would happen if a large electrical discharge was applied to them? Do they have internal ESD protection? Is the path of least resistance away from the internal circuitry? Are they isolated or connected to the local earth?
Ports like HDMI and USB need protection! The results of ESD will affect communication if not in place!

 

Surges, Transients, Dips and interrupts.

These are generally applied to the mains but can be applied to cables contact us for more information on cables. Large voltages and disruptions are applied to the mains to simulate possible variations on the mains system. These include spikes and interrupts in varying levels and periods you should consider how the EUT will be effected by such an event. Here is a list of events you should consider what happens if the power..

• Drops out for a short period?
• Spikes extremely high for a short period?
• Changes to half or a quarter of the expected voltage?

Ideally the EUT should not be effected at all and the EUT power supply will compensate for the change. But this is not the always the case, be prepared for the unit to reset or turn off completely in such an event. Consider the consequences of such an action.

• Will it be dangerous for example effecting a critical operation?
• Can it corrupt the EUT’s operation?
• Could it damage the unit or PSU?

 

EMI (Electro Magnetic Interference – Emissions)

The EUT must not affect other equipment around it during operation. For example, if the unit is producing a transmission at a particular frequency this frequency and all its harmonics must not interfere with any other equipment that works at the same frequency. There are some exceptions for fundamental frequencies that are needed to perform the product’s operation but any harmonics or noise generated are not allowed. Often it’s difficult to assess for radiated emissions before testing but some good practice is to check the unit has the following.

• Shielded cables for signals
• No unintentional antennas
• Decent shielding around noisy components
• Good ground planes

 

Often datasheets will give good examples of best practice for laying out a circuit and terminating or reducing EMC interference.

 

EMS (Electro Magnetic Susceptibility – Immunity)

Just like emissions the EUT must not be susceptible to interference getting into the EUT. Frequencies of significant levels are applied to the EUT across a wide frequency range to check its performance. You should consider the effects of another frequency at any operational frequencies?

• Will it block or disrupt the communication?
• Could it change the result and corrupt the communication?

Again, it’s often difficult to know for sure, but as above adequate shielding and best practice design should minimise any effects.

 

Preparation – Part 2

Before attending the lab to begin EMC testing consider the following.

• Bring spare units, EMC testing can and does lead to destruction of equipment!
• Spare fuses!
• Tools to service or apply countermeasures!
• The unit tested is going to be your Golden Sample. This means that ideally you want to keep this unit unchanged and stored safely, so that you can retest the unit in the future if any problems arise.
• The EUT should be the final build (Ideally) any significant changes in the future will require retesting!
• Its clear how the unit operates and what modes of operation are to be tested!
• Have you considered all the terminations and auxiliary equipment?

This is just a guide and hopefully will help you understand what to expect. But it’s not intended to be everything as every case is different. That’s why the Gainspeed staff are here to advise and guide you through every step.

Contact us today and good luck!

 

 

 

 

 

Posted in EMC Directive, News |

List of Harmonised Standards for the new EMC Directive (2014/30/EU) published in the OJ

A list of Harmonised Standards for the new EMC Directive (2014/30/EU) was published in the Official Journal on 13th May 2016.

Compared to the last list published for the old EMC Directive (2004/108/EC) there are:

Some observations

It appears some standards have been removed for two reasons:

  1. They have expired, or
  2.  They will be moved to the Radio Equipment Directive, including..
  • EN 55013:2013 – Sound and television broadcast receivers and associated equipment – Radio disturbance characteristics – Limits and methods of measurement
  • EN 55020:2007 – (and amendments) Sound and television broadcast receivers and associated equipment – Immunity characteristics – Limits and methods of measurement
  • EN 55022:2010 – Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement
  • EN 55032:2012 – Electromagnetic compatibility of multimedia equipment – Emission requirements
  • EN 55103-1:2009 (and amendments) Electromagnetic compatibility – Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use – Part 1: Emissions

We are now in a one year transition for the Radio Equipment Directive.

This means that for Products within OLD/NEW LVD/EMCD that will be within the RED, there is a choice of which Directive(s) to apply when considering products placed on the market and applicable Directive(s)

between 20 April 2016 and 12 June 2016

  • new LVD/EMCD

between 13 June 2016 and 12 June 2017

  • RED or new LVD/EMCD

after 12 June 2017

  • RED

However, there are now no harmonised standards under the new EMC Directive (2014/30/EU) for:

  • Sound and television broadcast receivers and associated equipment

Also there are no harmonised emission standards under the new EMC Directive (2014/30/EU) for:

  • Information technology equipment
  • multimedia equipment
  • Audio, video, audio-visual and entertainment lighting control apparatus for professional use

So its unclear if there is a transition period at this time.

New List of Harmonised Standards for the Medical Devices Directive, (93/42/EEC) published in the Official Journal

A new list of Harmonised Standards for the Medical Devices Directive, (93/42/EEC) was published in the Official Journal on May 13, 2016 – OJ C173

9 new standards have been added:

  • EN 556-2:2015 (new) Sterilization of medical devices – Requirements for medical devices to be designated ”STERILE” – Part 2: Requirements for aseptically processed medical devices
  • EN 1865-1:2010+A1:2015 (new) Patient handling equipment used in road ambulances – Part 1: General stretcher systems and patient handling equipment
  • EN 1865-2:2010+A1:2015 (new) Patient handling equipment used in road ambulances – Part 2: Power assisted stretcher
  • EN ISO 3826-4:2015 (new) Plastics collapsible containers for human blood and blood components – Part 4: Aphaeresis blood bag systems with integrated features (ISO 3826-4:2015)
  • EN ISO 11137-1:2015 (new) Sterilization of health care products – Radiation – Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices (ISO 11137-1:2006, including Amd 1:2013)
  • EN ISO 11137-2:2015 (new) Sterilization of health care products – Radiation – Part 2: Establishing the sterilization dose (ISO 11137-2:2013)
  • EN ISO 13408-1:2015 (new) Aseptic processing of health care products – Part 1: General requirements (ISO 13408-1:2008, including Amd 1:2013)
  • EN ISO 13408-7:2015 (new) Aseptic processing of health care products – Part 7: Alternative processes for medical devices and combination products (ISO 13408-7:2012)
  • EN 60601-1-2:2015 (new) Medical electrical equipment – Part 1-2: General requirements for basic safety and essential performance – Collateral
    Standard: Electromagnetic disturbances – Requirements and tests